Product Information

 

         Quality & Comfort

 

Fraser-Johnston® Heating & Air Conditioning home comfort systems are designed and built to provide maximum quality, comfort, and efficiency to your home. Whether you're looking for a furnace, an air conditioner or a complete heating and cooling solution , your Fraser-Johnston® Dealer can evaluate factors such as your home's size, age, number of rooms, regional climate, and utility costs to select the best system for your home.

   

 

Get Certified

 
 

Nate

NATE
Fraser-Johnston® encourages professionalism through North American Technician Excellence, Inc.(NATE). NATE is the leading certification program for technicians in the heating, ventilation, air-conditioning and refrigeration (HVAC/R) industry, and is the only test supported by the entire industry.

Energy Star

ENERGY STAR
Earning the ENERGY STAR® means products meet strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the Department of Energy. When compared to standard models, ENERGY STAR® products are between 15 and 25% more efficient. This model meets ENERGY STAR® requirements for energy efficiency.



ISO 9001 Certified Company
   

 

Selected Product Details and Documentation

 
 

Fraser-Johnston Heating and Air Conditioning

 

Product Details
MODELTM9V
PRODUCT96% 2 Stage VS Multi-Position Gas Furnace
 
 
 
CAPACITY40 - 120 MBH Input
EFFICIENCY96% AFUE
WARRANTIES 
CompressorNA
Heat ExchangerLifetime
Parts10-Year Limited*
 
DESCRIPTION 
 

These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.

These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.

These units are Category IV listed and may be vented either through side wall or roof applications using approved plastic combustion air and venr piping.

BENEFITS 
 
  • Two stage heating operation includes two stage gas valve, two stage inducer operation and variable speed ECM blower operation. Adjustable delay timer allows two stage operation with a single stage thermostat.
  • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
  • Compact, easy to install, ideal height 33" tall cabinet.
  • ECM variable speed drive for cooling SEER enhancement, improved comfort with optional airflow delay profiles, and continuous fan options for IAQ performance.
  • Easy access to controls to connect power/control wiring.
  • Built-in, high level self diagnostics with fault code display.
  • Low unit amp requirement for easy replacement application.
  • All models are convertable to use propane (LP) gas.
  • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
  • 100% shut off main gas valve for extra safety.
  • 24V, 40 VA control transformer and blower relay supplied for add-on cooling.
  • Hi-tech tubular aluminized steel primary heat exchanger with stainless steel tube/aluminum fin secondary heat exchanger for outstanding efficiency.
  • Solid removable bottom panel allows easy conversion.
  • Airflow leakage less than 1% of nominal airflow for ductblaster conditions.
  • No knockouts to deal with, making installation easier.
  • Movable duct connector flanges for application flexibility.
  • Quiet inducer operation, burner, and blower operation.
  • Inducer rotates for easy conversion of venting options.
  • Fully supported blower assembly for easy access and removal of blower.
  • External air filters used for maximum flexibility in meeting customers IAQ needs.
  • Insulated blower compartment for thermal and acoustic performance.
  • 1/4 turn knobs provided for easy independent door removal.
  • Internal condensate trap design (patent pending) provides condensate management options, easy visual operation check, and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent or condensate blockage.
  • Venting applications maybe installed as either 2 pipe sealed combustion or single pipe vent using indoor combustion air.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate.

 

PRODUCT DOCUMENTATION
DESCRIPTIONFILE NAMEFILE KB
Consumer Brochure - Fraser-Johnston Reliant™ Residential Gas Furnaces TP9C, TM9M, TM9Y, TPLC, TM8Y, TM8V, TM9V, TM9T, TM9E, TG9S, TM8T, TM8X & TG8SPUBL-8710-A-0817.PDF899
Sell Sheet - 33" Gas Furnaces 80% and Up to 97% AFUE ModelsPUBL-6298-B-0713.PDF804
Installation Accessory - 1HT0901 Side Wall Vent Kit (1-1/2”, 2” or 3” vent systems)276015_035-20614-001-A-0804.PDF47
Installation Accessory - 1HT0902 Side Wall Vent Kit (1-1/2” or 2” vent systems)276016-UAI-A-1006.pdf125
Installation Accessory - 1NP0347 Propane Conversion - Induced Combustion Furnaces1065603-UAI-C-1015.PDF219
Installation Accessory - 1CT0302, 1CT0303 Concentric Vent Termination66641-UIM-F-0905_035-14287-000.pdf73
Installation Accessory - 1CB0514, 17, 21, & 24 Floor Base Accessory397059-UAI-A-0408.pdf54
Installation Accessory - 1SR0200, 1BR0114, 1BR0214, 1BR0117, 1BR0217, 1BR0121, 1BR0221, 1BR0124, & 1BR0224 Filter Rack Kits171002-UAI-B-0514.PDF49
Installation Accessory - 1SR0402 Filter Frame430731-UAI-A-0908.pdf38
Installation Accessory - 1SR0200 Filter Frame1135041-UAI-B-0616.PDF45
Installation Accessory - S1-32642583000 and S1-3264594000 Inducer Replacement Kits035-24175-001-A-1014.PDF98
Installation Accessory - Burner Alignment Bracket for use with All 33" Gas Furnaces826018-uai-a-1111.pdf106
Installation Accessory - S1-37327905001 thru S1-37327905006 (2 Cell thru 7 Cell) 33" Burner Box Kits for all 33" Gas Furnaces1148943-UAI-A-0514.PDF99
Installation Accessory - S1-37327813001 Furnace Label Kit341248-UAI-A-0707.pdf11
Installation Accessory - S1-1PS3308 (96%) and 1PS3309 (80%) High Altitude Application Conversion for Two Stage Furnaces035-22764-001-D-0110.pdf23
NEUTRALIZER KIT (S1-1NK0301)035-24119-001-A-0814.PDF16
Cladding Accessory - S1-37327901001 (York), S1-37327901003 (Coleman) & S1-37327901002 (Luxaire)518112-UAI-B-0914.PDF42
Guide d' Installations - S1-1CT0302-636/S1-1CT0303-636 Terminaison D'Event Concentrique435695-UAIF-A-1108.pdf71
Installation Accessory - 1BR0514/614, 1BR0517/617, 1BR0521/621 & 1BR0524/624 External Bottom Mount Filter Frame Accessory506177-UAI-B-0817.PDF37
Installation Accessory - S1-32924441000 STAINLESS STEEL NATURAL GAS BURNER KIT035-21367-001-B-0412.PDF12
Installation Accessory - S1-32926889000 STAINLESS STEEL PROPANE LP BURNER KIT035-24610-001-A-0416.PDF65
Installation Accessory - S1-33102955000 Ignition Control P/N035-22272-001-A-0409.pdf141
Installation Accessory - Control Board Kit (P/N S1-33103012000) for use with all Communicating Two-Stage Variable Speed Models035-23655-001-B-0614.PDF151
Installation Accessory - Ignition Control (P/N S1-33102977000) for use with all Two-Stage Non-Communicating Variable Speed Furnaces035-23069-001-C-1216.PDF124
Accessory Kit Installation Manual - All 33" Furnace Model Burner Box Wrapper Kits S1-37339477001(2 Cell), S1-37339477002 (3 Cell), S1-37339477003 (4 Cell), S1-37339477004 (5 Cell), S1-37339477005 (6 Cell), S1-37339477006 (7 Cell)5352742-UAI-A-0417.PDF48
Installation Manual - TM9V*C Two Stage Variable Speed ECM Residential Gas Furnaces (96% AFUE Multi-position)5402851-UIM-A-0917.PDF2617
Installation Manual - TM9V Two Stage Variable Speed ECM Residential Gas Furnaces (96% AFUE Multi-position) 1083294-UIM-I-0817.PDF2434
Quick Reference Guide - TM9V 96% Two Stage Variable Speed ECM Multi-position Residential Gas Furnaces (33" Tall)5402927-URG-A-0917.PDF170
Quick Reference Guide - 96% AFUE Two Stage Variable Speed Multi-Position 33" Gas Furnaces1083301-URG-A-0114.PDF258
Repair Parts - TM9V Series 95% AFUE Two Stage Variable Speed Multi-Position 33" Gas Furnaces "Style A"035-22194-001-J-0917.PDF747
Repair Parts - TM9T and TM9V Series Furnace Pressure Switch Wiring Harness.035-22781-001-A-1009.pdf83
Repair Parts - Condensate Pan Replacement for Use with All Condensing - 95+ AFUE 33" Gas Furnaces035-22785-002-a-0511.pdf82
REPAIR PARTS - TM9V SERIES 96% 2 STAGE VARIABLE SPEED MULTI-POSITION 33" NATURAL GAS FURNACES W/COMM (STYLE A)035-23654-001-F-0917.PDF987
Repair Parts - TM9V Series 95% Two Stage Variable Speed 33" Nat Gas Furnaces (Style B)035-23626-001-A-0313.PDF987
REPAIR PARTS - TM9V SERIES 96% TWO STAGE VARIABLE SPEED ECM MULIT-POSTION 33" NATURAL GAS FURACES W/COMM, GEN 2 (STYLE A)035-26490-001-A-1017.PDF713
Technial Guide - TM9V*C 96% AFUE Two Stage Variable Speed ECM Residential Gas Furnaces Multi-Postion5425619-BTG-A-0917.PDF214
Technical Guide - TM9V 96% AFUE 2 Stage Variable Speed Multi-Position Gas Furnaces700709-BTG-I-1016.PDF186
User Manual - All Residential Multi-Position 33" Gas Furnaces1010352-UUM-I-0917.PDF2133
Fraser-Johnston 2015-16 Tax Credit Certificate68880
Submittal Data Sheet - TM9V 96% AFUE 2 Stage Variable Speed Multi-Position Gas Furnaces700710-USD-D-0615.PDF95
Submittal Data Sheet - TM9V*C 96% Two Stage Variable Speed ECM Residential Multi-Position Gas Furnaces5425620-USD-A-0917.PDF111
Price Pages - GUARDIAN, FJ SERIES, 95% to 98% AFUE 33" GAS FIRED FURNACES_036-13944-004-F-1017-FJ.XLSX505