Product Information

 

         Quality & Comfort

 

Fraser-Johnston® Heating & Air Conditioning home comfort systems are designed and built to provide maximum quality, comfort, and efficiency to your home. Whether you're looking for a furnace, an air conditioner or a complete heating and cooling solution , your Fraser-Johnston® Dealer can evaluate factors such as your home's size, age, number of rooms, regional climate, and utility costs to select the best system for your home.

   

 

Get Certified

 
 

Nate

NATE
Fraser-Johnston® encourages professionalism through North American Technician Excellence, Inc.(NATE). NATE is the leading certification program for technicians in the heating, ventilation, air-conditioning and refrigeration (HVAC/R) industry, and is the only test supported by the entire industry.

Energy Star

ENERGY STAR
Earning the ENERGY STAR® means products meet strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the Department of Energy. When compared to standard models, ENERGY STAR® products are between 15 and 25% more efficient. This model meets ENERGY STAR® requirements for energy efficiency.



ISO 9001 Certified Company
   

 

Selected Product Details and Documentation

 
 

Fraser-Johnston Heating and Air Conditioning

 

Product Details
MODELTM9M
PRODUCT97% AFUE Modulating PSC Multi-Position Gas Furnace
 
 
 
CAPACITY60 - 120 MBH Input
EFFICIENCY97% AFUE
WARRANTIES 
CompressorN/A
Heat ExchangerLifetime
Parts10-Year Limited*
 
DESCRIPTION 
 

These TM9M compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications. Modulating heating operation (100 stages)with PSC motor acting like a variable speed ECM in heating mode provides outstanding efficiency and comfort.

These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.

Designed and certified as Category IV furnaces, these TM9M models may be installed as direct vent systems through side wall or roof applications using approved plastic combustion air and vent materials.

BENEFITS 
 
  • "100 stage" Modulating PSC furnace design.
  • 2nd generation Modulating Control .
  • White Rodgers 36J27 Gas Valve does not require change out for LP applications.
  • Compact 33” Height and Standard Cabinet Widths.
  • Multi-Position Design With Minimal Conversion Requirements.
  • Airflow Leakage Rate of Less Than 1% of Total Airflow @ 1” ESP.
  • 4 Speed PSC Motor with Large, Quiet Blower.
  • Fully-Supported, Slide-Out Blower Assembly for Easy Service Access.
  • Tubular Aluminized Steel Primary Heat Exchanger.
  • High-Level Self-Diagnostic Controls With Fault Codes.
  • Sharp Edges Have Been Eliminated By Folding and Flattening the Sheet Metal.
  • Fully-Gasketed, Independent Access Doors With View Ports.
  • External Air Filters (Not Included) Provide Flexibility for IAQ Needs.
  • All Models Are Propane Convertible.
  • Lo-Nox Specific Code Requirements meet for all models.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate.

 

PRODUCT DOCUMENTATION
DESCRIPTIONFILE NAMEFILE KB
Consumer Brochure - Fraser-Johnston Reliant™ Residential Gas Furnaces TP9C, TM9M, TM9Y, TPLC, TM8Y, TM8V, TM9V, TM9T, TM9E, TG9S, TM8T, TM8X & TG8SPUBL-8710-A-0817.PDF899
Sell Sheet - 33" Gas Furnaces 80% and Up to 97% AFUE ModelsPUBL-6298-B-0713.PDF804
NEUTRALIZER KIT (S1-1NK0301)035-24119-001-A-0814.PDF16
Cladding Accessory - S1-37327901001 (York), S1-37327901003 (Coleman) & S1-37327901002 (Luxaire)518112-UAI-B-0914.PDF42
Installation Accessory - Burner Alignment Bracket for use with All 33" Gas Furnaces826018-uai-a-1111.pdf106
Installation Accessory - S1-32642583000 and S1-3264594000 Inducer Replacement Kits035-24175-001-A-1014.PDF98
Installation Accessory - S1-37327813001 Furnace Label Kit341248-UAI-A-0707.pdf11
Installation Accessory - 1SR0200 Filter Frame1135041-UAI-B-0616.PDF45
Installation Accessory - 1SR0402 Filter Frame430731-UAI-A-0908.pdf38
Installation Accessory - 1SR0200, 1BR0114, 1BR0214, 1BR0117, 1BR0217, 1BR0121, 1BR0221, 1BR0124, & 1BR0224 Filter Rack Kits171002-UAI-B-0514.PDF49
Installation Accessory - 1HT0901 Side Wall Vent Kit (1-1/2”, 2” or 3” vent systems)276015_035-20614-001-A-0804.PDF47
Installation Accessory - 1HT0902 Side Wall Vent Kit (1-1/2” or 2” vent systems)276016-UAI-A-1006.pdf125
Installation Accessory - 1CB0514, 17, 21, & 24 Floor Base Accessory397059-UAI-A-0408.pdf54
Installation Accessory - 1CT0302, 1CT0303 Concentric Vent Termination66641-UIM-F-0905_035-14287-000.pdf73
Installation Accessory - 1BR0514/614, 1BR0517/617, 1BR0521/621 & 1BR0524/624 External Bottom Mount Filter Frame Accessory506177-UAI-B-0817.PDF37
Guide d' Installations - S1-1CT0302-636/S1-1CT0303-636 Terminaison D'Event Concentrique435695-UAIF-A-1108.pdf71
Installation Accessory - S1-32926889000 STAINLESS STEEL PROPANE LP BURNER KIT035-24610-001-A-0416.PDF65
Installation Accessory - S1-32924441000 STAINLESS STEEL NATURAL GAS BURNER KIT035-21367-001-B-0412.PDF12
Accessory Kit Installation Manual - All 33" Furnace Model Burner Box Wrapper Kits S1-37339477001(2 Cell), S1-37339477002 (3 Cell), S1-37339477003 (4 Cell), S1-37339477004 (5 Cell), S1-37339477005 (6 Cell), S1-37339477006 (7 Cell)5352742-UAI-A-0417.PDF48
Installation - Accessory - Pressure Switch Conversion - For use with all 33” - 95% Modulating Gas Furnaces035-23120-001-C-0214.PDF98
Installation Accessory - 1NP0680 Propane Conversion for Use With All Modulating Models With White Rodgers 36E27 Gas Valve247589-UAI-F-0210.pdf114
Installation Accessory - S1-37327804001 RF Interference Service Kit035-21358-001-A-0507.pdf21
Installation Accessory - S1-33102972000 (PSC) Control Board Kit For Use With All Modulating 33” 97%+ Furnaces (2nd Generation)035-22814-001-b-0411.pdf120
Installation Accessory - Accessory Kit Manual for S1-37327916001 (PSC Models) and S1-37327916002 (ECM Models) Modulating Furnace Control Board Gas Valve Upgrade Kits035-23085-002-A-0913.PDF50
Installation Accessory - S1-1NP0681 Propane Conversion Accessory Kit for Use With All Modulating Models With White Rodgers 36J27 Gas Valve528014-uai-c-1210.pdf161
Installation Accessory - S1-33102936001 (ECM) & S1-33102937001 (PSC) Control Board Kit for use with all Modulating 33” 80% and 97%+ Furnaces035-22217-001-c-0111.pdf226
Installation Manual - TM9M Modulating PSC Residential Gas Furnace (97% AFUE Multi-Position)1083293-UIM-F-0817.PDF2286
Reference Guide - 97% AFUE Modulating PSC Multi-Position 33" Gas Furnaces1083299-URG-A-0114.PDF455
Repair Parts - TM9M Series 97% AFUE (PSC) 33" Modulating Multi-Position Gas Furnaces "Style A"035-22084-001-K-0317.PDF897
Repair Parts - Condensate Pan Replacement for Use with All Condensing - 95+ AFUE 33" Gas Furnaces035-22785-002-a-0511.pdf82
Repair Parts - TM9M Series 97% (PSC) Modulating Multi-Position Gas Furnaces, 2nd Generation, "Style A"035-22813-001-F-0317.PDF871
Technical Guide - TM9M 97% AFUE Modulating Multi-Position 33" PSC Gas Furnaces563716-BTG-E-1016.PDF123
Submittal Data Sheet - TM9M 97% Modulating Gas-Fired Multi-Position Gas Furnaces (PSC Motor)563715-USD-B-0512.PDF90
Price Pages - GUARDIAN, FJ SERIES, 95% to 98% AFUE 33" GAS FIRED FURNACES_036-13944-004-F-1017-FJ.XLSX505