Product Information

 

         Quality & Comfort

 

Fraser-Johnston® Heating & Air Conditioning home comfort systems are designed and built to provide maximum quality, comfort, and efficiency to your home. Whether you're looking for a furnace, an air conditioner or a complete heating and cooling solution , your Fraser-Johnston® Dealer can evaluate factors such as your home's size, age, number of rooms, regional climate, and utility costs to select the best system for your home.

   

 

Get Certified

 
 

Nate

NATE
Fraser-Johnston® encourages professionalism through North American Technician Excellence, Inc.(NATE). NATE is the leading certification program for technicians in the heating, ventilation, air-conditioning and refrigeration (HVAC/R) industry, and is the only test supported by the entire industry.

Energy Star

ENERGY STAR
Earning the ENERGY STAR® means products meet strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the Department of Energy. When compared to standard models, ENERGY STAR® products are between 15 and 25% more efficient. This model meets ENERGY STAR® requirements for energy efficiency.



ISO 9001 Certified Company
   

 

Selected Product Details and Documentation

 
 

Fraser-Johnston Heating and Air Conditioning

 

Product Details
MODELTM8Y
PRODUCTTwo Stage STD ECM 80% Multi-Position Gas Furnace
 
 
 
CAPACITY60 - 120 MBH Input
EFFICIENCY80% AFUE
WARRANTIES 
CompressorN/A
Heat Exchanger20 Years
Parts10 Year Limited *
 
DESCRIPTION 
 

These compact units employ induced combustion, reliable hot surface ignition and high heat transfer aluminized tubular heat exchangers. The units are factory shipped for installation in upflow or horizontal applications and may be converted for downflow applications.

These furnaces are designed for residential installation in a basement, closet, alcove, attic, recreation room or garage and are also ideal for commercial applications. All units are factory assembled, wired and tested to assure safe dependable and economical installation and operation.

These units are Category I listed and may be common vented with another gas appliance as allowed by the National Fuel Gas Code.

BENEFITS 
 
  • Easily applied in upflow, horizontal left or right, or downflow installation with minimal conversion necessary.
  • Compact, easy to install, ideal height 33" tall cabinet.
  • Blower-off delay for cooling SEER improvement.
  • Easy access to controls to connect power/control wiring.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Low unit amp requirement for easy replacement application.
  • All models are convertable to use propane (LP) gas.
  • Electronic Hot Surface Ignition saves fuel cost with increased dependability and reliability.
  • 100% shut off main gas valve for extra safety.
  • 24V, 40 VA control transformer and blower relay supplied for add-on cooling.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch.
  • Solid removable bottom panel allows easy conversion.
  • Low NOx models have been designed to meet specific code requirements.
  • Airflow leakage less than 1% of total airflow at ductblaster conditions.
  • No knockouts to deal with, making installation easier.
  • Movable duct connector flanges for application flexibility.
  • Quiet inducer operation.
  • Inducer rotates for easy conversion of venting options.
  • Fully supported blower assembly for easy access and removal of blower.
  • External air filters used for maximum flexibility in meeting customers IAQ needs.
  • Venting applications - may be installed as a common vent with other gas-fired appliances or use a masonry chimney.
  • 1/4 turn knobs provided for easy door removal.
  • Insulated blower compartment for thermal and acoustic performance.

*Must be installed on or after May 1st, 2009, and registered online within 90 days of installation. Otherwise, the warranty reverts to the standard warranty as published in the product warranty certificate.

 

PRODUCT DOCUMENTATION
DESCRIPTIONFILE NAMEFILE KB
Consumer Brochure - Fraser-Johnston Reliantâ„¢ Residential Gas Furnaces TP9C, TM9M, TM9Y, TPLC, TM8Y, TM8V, TM9V, TM9T, TM9E, TG9S, TM8T, TM8X & TG8SPUBL-8710-A-0817.PDF899
Cladding Accessory - S1-37327901001 (York), S1-37327901003 (Coleman) & S1-37327901002 (Luxaire)518112-UAI-B-0914.PDF42
Installation Accessory - S1-37327905001 thru S1-37327905006 (2 Cell thru 7 Cell) 33" Burner Box Kits for all 33" Gas Furnaces1148943-UAI-A-0514.PDF99
Installation Accessory - 1SR0402 Filter Frame430731-UAI-A-0908.pdf38
Installation Accessory - Burner Alignment Bracket for use with All 33" Gas Furnaces826018-uai-a-1111.pdf106
Installation Accessory - S1-37327813001 Furnace Label Kit341248-UAI-A-0707.pdf11
Installation Accessory - 1CB0514, 17, 21, & 24 Floor Base Accessory397059-UAI-A-0408.pdf54
Installation Accessory - 1BR0514/614, 1BR0517/617, 1BR0521/621 & 1BR0524/624 External Bottom Mount Filter Frame Accessory506177-UAI-B-0817.PDF37
Installation Accessory - 1SR0200, 1BR0114, 1BR0214, 1BR0117, 1BR0217, 1BR0121, 1BR0221, 1BR0124, & 1BR0224 Filter Rack Kits171002-UAI-B-0514.PDF49
Installation Accessory - 1SR0200 Filter Frame1135041-UAI-B-0616.PDF45
Installation Accessory - 1NP0347 Propane Conversion - Induced Combustion Furnaces1065603-UAI-C-1015.PDF219
Installation Accessory - 1CK0604 Masonry Chimney Draft Hood Kit035-17452-000-E-0616.PDF84
Installation Accessory - S1-32924441000 STAINLESS STEEL NATURAL GAS BURNER KIT035-21367-001-B-0412.PDF12
Installation Accessory - S1-32926889000 STAINLESS STEEL PROPANE LP BURNER KIT035-24610-001-A-0416.PDF65
Accessory Kit Installation Manual - All 33" Furnace Model Burner Box Wrapper Kits S1-37339477001(2 Cell), S1-37339477002 (3 Cell), S1-37339477003 (4 Cell), S1-37339477004 (5 Cell), S1-37339477005 (6 Cell), S1-37339477006 (7 Cell)5352742-UAI-A-0417.PDF48
Installation Manual - TM8Y Two Stage Standard ECM 80% AFUE Multi-Position / Low NOx Gas Furnaces5052632-UIM-D-0217.PDF1372
Quick Reference Guide - TM8Y Two Stage Standard ECM Multi-Position Standard and Low NOx Gas Furnaces5052614-URG-B-1115.PDF197
Price Pages - GUARDIAN, FJ SERIES036-13942-004-E-0617-FJ.XLSX445
REPAIR PARTS - TM8Y SERIES 80% TWO STAGE MP 33" NG FURNACES W/HI-EFF MOTORS (STYLE A)035-24552-001-C-1115.PDF968
Technical Guide - TM8Y Two Stage Standard ECM Multi-Position Standard and Low NOx Gas Furnaces5129595-BTG-C-0616.PDF139
User Manual - All Residential Multi-Position 33" Gas Furnaces1010352-UUM-I-0917.PDF2133
Fraser-Johnston 2015-16 Tax Credit Certificate68880
Submittal Data Sheet - TM8Y Two Stage Standard ECM Multi-Position Standard and Low NOx Gas Furnaces5129596-USD-A-0815.PDF102