         Quality & Comfort

 

Fraser-Johnston® Heating & Air Conditioning home comfort systems are designed and built to provide maximum quality, comfort, and efficiency to your home. Whether you're looking for a furnace, an air conditioner or a complete heating and cooling solution , your Fraser-Johnston® Dealer can evaluate factors such as your home's size, age, number of rooms, regional climate, and utility costs to select the best system for your home.

   

 

Get Certified

 
 

Nate

NATE
Fraser-Johnston® encourages professionalism through North American Technician Excellence, Inc.(NATE). NATE is the leading certification program for technicians in the heating, ventilation, air-conditioning and refrigeration (HVAC/R) industry, and is the only test supported by the entire industry.

Energy Star

ENERGY STAR
Earning the ENERGY STAR® means products meet strict energy efficiency guidelines set by the U.S. Environmental Protection Agency and the Department of Energy. When compared to standard models, ENERGY STAR® products are between 15 and 25% more efficient. This model meets ENERGY STAR® requirements for energy efficiency.



ISO 9001 Certified Company
   

 

Selected Product Details and Documentation

 
 

Fraser-Johnston Heating and Air Conditioning

 

Product Details
MODELPHG6
PRODUCTPHG6 Series - 2 - 5 Ton - R410a - HP/Gas
 
 
 
CAPACITY2 - 5 Ton
EFFICIENCY16.0 SEER/12.5. EER, 81% AFUE
WARRANTIES 
Compressor10 Years with Reg.*
Heat ExchangerLifetime
Parts10 Years with Reg.*
 
DESCRIPTION 
 These packaged HP cooling/ gas heating air conditioners are designed for outdoor installation. Only utility and duct connections are required at the point of installation.
BENEFITS 
 
  • Operating Efficiency - All PHG6 model gas units provide a minimum AFUE of 81.0% in heating and 16.0 SEER, 12.5 EER, 8.2 HSPF rating for cooling  or heating operation. All models meet current California Low-Nox requirements of 40 ng/joule emission level for Air Quality Management Districts.
  • On Site Flexibility - All model sizes use a compact design cabinet in one of two footprints. This provides installer flexibility for placing the proper tonnage unit on curbs or pads with the smallest footprint after the internal load has been determined. Field convertible duct connections from side with less inventory.
  • Lower Installation Cost - Installation time and costs are reduced by easy power and control wiring connections. The small base dimension means less space is required on the ground or roof. All units are completely wired, charged with R-410A and tested prior to shipment. Test stations using a state-of-the-art computerized process system are used to insure product quality. Refrigerant charge and component part numbers are verified via computers at assembly. Vital run test statistics such as system pressure, motor currents, air velocity and temperature, unit vibration, and gas system safeties are monitored and recorded by the system to insure unit performance. Equal size, side supply and return duct connections allows easy hook-up of ducts to match low crawl spaces without transition pieces.
  • Utility Connections Made Easy - Gas and electric utility access provided through the bottom as well as the side of the unit. Utility connections can be made quickly and with a minimum amount of field labor. A field supplied and field installed electrical disconnect switch must be installed.
  • Convertible Airflow Design - The bottom duct openings are covered when they leave the factory, ready to be used for a side supply/side return application. If a bottom supply/bottom return application is desired, simply remove the two panels from the bottom of the unit and place them in the side supply/  side return duct openings. No panel cutting is required and
    no accessory panel is necessary. Convertible airflow design allows maximum field flexibility and minimum inventory.
  • Condensate Pan - A corrosion-resistant, long-lasting, watertight pan is positioned below the evaporator coil to collect and drain all condensate, preventing build-up of stagnant condensate. The condensate pan conforms to ASHRAE 62-89 standards (Ventilation for Acceptable Indoor Air Quality).
  • Condensate Drain - The 3/4 inch NPTF connection is rigidly mounted to assure proper fit and leak tight seal.
  • Durable Finish - The cabinet is made of G90 galvanized steel with a powder paint coating for appearance and protection. The pre-treated galvanized steel provides a better paint to-steel bond, which resists corrosion and rust creep. Powder paint finish ensures less fading when exposed to sunlight, and provides superior corrosion resistance (1000 hour salt spray tested).

NOTE: Please refer to Technical Guide for more additional features.

 

PRODUCT DOCUMENTATION
DESCRIPTIONFILE NAMEFILE KB
Service Application Data - Residential Package HP/Gas & HP/Electric5279144-UAG-B-0517.PDF396
Consumer Brochoure - Fraser-Johnston LX Series Residential Package Equipment 2 - 5 Ton 14 - 16 SEERPUBL-7536-E-0117.PDF1074
Installation Accessory - Field Installed Barometric Relief Hood (S1-1RD0501)5203032-UAI-A-0416 (YKIBR02).PDF28
Accessory Kit Installation Manual - PCG & PHG Condensate Management Vestibule Insulation Kit (S1-37339474001)5335606-UAI-A-0417.PDF356
Installation Accessory - Single/Dual Enthalpy Kit (S1-2EC04700624)1199085-UAI-A-0115 (YKIDE49).PDF114
Installation Accessory - Single Dry Bulb Kit (S1-2EC04700724)1199086-UAI-A-0115 (YKITS49).PDF22
Installation Accessory - Motorized Outside Air Damper (S1-2MD04705124 / S1-2MD04705224)1199089-UAI-A-0115 (YKI35OM49).PDF1002
Installation Accessory - Manual Outside Air Damper (S1-1FA0501 / S1-1FA0502)1199090-UAI-C-0517 (YKI35OA49).PDF153
Installation Accessory - Downflow Economizer Kit (S1-2EE04708424 / S1-2EE04708524)1199083-UAI-B-0416 (YKIGEJ49).PDF438
Installation Accessory - Horizontal Economizer (S1-2EE04708624 / S1-2EE04708724)1199084-UAI-B-0416(YKIHEJ49_.PDF254
Installation Accessory - CO2 Sensor Kit (S1-2AQ04700824)1199087-UAI-B-0317 (YKICO206).PDF332
Installation Accessory - Field Installed Rectangle to Round Adaptor (Downflow) S1-1AK0108 / S1-1AK01091199092-UAI-B-0615 (YKITRN49).PDF39
Installation Accessory - Field Installed Round to Rectangle Adaptor (Horizontal) S1-1AK0110 / S1-1AK01111199091-UAI-B-0615 (YKITAK49).PDF148
Installation Accessory - "Hinge" Roof Curb (S1-1RC0501 / S1-1RC0502 / S1-1RC0503 / S1-1RC0504)1199093-UAI-B-0515 (YKICRB49).PDF68
Installation Accessory - Roof Curb Adapter Field In stalled Kit (S1-1TC0101-S1-1TC0108)5007749-UAI-B-0816 (YKICADP01).PDF70
Installation Accessory - Roof Curb Adapter Field In stalled Kit (S1-1TC0111-S1-1TC0118)5113377-UAI-B-0917 (YKICADP01P).PDF33
Installation Manual - PHG6 Single Package Heat Pump / Gas Heat 2 thru 5 Tons - 208/230V - 1 Phase5322625-UIM-A-0417.PDF3645
REPAIR PARTS - PHG6 SERIES 16 SEER SINGLE PACKAGED DUAL FUEL HEAT PUMPS, R-410A (STYLE A)035-26463-001-A-0317.PDF2638
Technical Guide - PHG6 Single Package Heat Pump / Gas Heat 16 SEER - R-410A - 208/230V-1Phase, 2 Thru 5 Nominal Tons / 50 Thru 125 MBH Heat Input5331899-BTG-C-1017.PDF2652
User Manual - Single Package HP & Gas - PHG*5132211-UUM-H-1017.PDF204
Submittal Data Sheet - PHG6 - 1 Phase Single Package Heat Pump / Gas Heat 16 SEER, 12.0 EER - R410A - 2 Thru 5 Tons5332150-USD-A-0417.PDF736